CloudWatch / Client / put_composite_alarm
put_composite_alarm#
- CloudWatch.Client.put_composite_alarm(**kwargs)#
Creates or updates a composite alarm. When you create a composite alarm, you specify a rule expression for the alarm that takes into account the alarm states of other alarms that you have created. The composite alarm goes into ALARM state only if all conditions of the rule are met.
The alarms specified in a composite alarm’s rule expression can include metric alarms and other composite alarms. The rule expression of a composite alarm can include as many as 100 underlying alarms. Any single alarm can be included in the rule expressions of as many as 150 composite alarms.
Using composite alarms can reduce alarm noise. You can create multiple metric alarms, and also create a composite alarm and set up alerts only for the composite alarm. For example, you could create a composite alarm that goes into ALARM state only when more than one of the underlying metric alarms are in ALARM state.
Composite alarms can take the following actions:
Notify Amazon SNS topics.
Invoke Lambda functions.
Create OpsItems in Systems Manager Ops Center.
Create incidents in Systems Manager Incident Manager.
Note
It is possible to create a loop or cycle of composite alarms, where composite alarm A depends on composite alarm B, and composite alarm B also depends on composite alarm A. In this scenario, you can’t delete any composite alarm that is part of the cycle because there is always still a composite alarm that depends on that alarm that you want to delete.
To get out of such a situation, you must break the cycle by changing the rule of one of the composite alarms in the cycle to remove a dependency that creates the cycle. The simplest change to make to break a cycle is to change the
AlarmRule
of one of the alarms tofalse
.Additionally, the evaluation of composite alarms stops if CloudWatch detects a cycle in the evaluation path.
When this operation creates an alarm, the alarm state is immediately set to
INSUFFICIENT_DATA
. The alarm is then evaluated and its state is set appropriately. Any actions associated with the new state are then executed. For a composite alarm, this initial time after creation is the only time that the alarm can be inINSUFFICIENT_DATA
state.When you update an existing alarm, its state is left unchanged, but the update completely overwrites the previous configuration of the alarm.
To use this operation, you must be signed on with the
cloudwatch:PutCompositeAlarm
permission that is scoped to*
. You can’t create a composite alarms if yourcloudwatch:PutCompositeAlarm
permission has a narrower scope.If you are an IAM user, you must have
iam:CreateServiceLinkedRole
to create a composite alarm that has Systems Manager OpsItem actions.See also: AWS API Documentation
Request Syntax
response = client.put_composite_alarm( ActionsEnabled=True|False, AlarmActions=[ 'string', ], AlarmDescription='string', AlarmName='string', AlarmRule='string', InsufficientDataActions=[ 'string', ], OKActions=[ 'string', ], Tags=[ { 'Key': 'string', 'Value': 'string' }, ], ActionsSuppressor='string', ActionsSuppressorWaitPeriod=123, ActionsSuppressorExtensionPeriod=123 )
- Parameters:
ActionsEnabled (boolean) – Indicates whether actions should be executed during any changes to the alarm state of the composite alarm. The default is
TRUE
.AlarmActions (list) –
The actions to execute when this alarm transitions to the
ALARM
state from any other state. Each action is specified as an Amazon Resource Name (ARN).Valid Values: ]
Amazon SNS actions:
arn:aws:sns:region:account-id:sns-topic-name
Lambda actions:
Invoke the latest version of a Lambda function:
arn:aws:lambda:region:account-id:function:function-name
Invoke a specific version of a Lambda function:
arn:aws:lambda:region:account-id:function:function-name:version-number
Invoke a function by using an alias Lambda function:
arn:aws:lambda:region:account-id:function:function-name:alias-name
Systems Manager actions:
arn:aws:ssm:region:account-id:opsitem:severity
(string) –
AlarmDescription (string) – The description for the composite alarm.
AlarmName (string) –
[REQUIRED]
The name for the composite alarm. This name must be unique within the Region.
AlarmRule (string) –
[REQUIRED]
An expression that specifies which other alarms are to be evaluated to determine this composite alarm’s state. For each alarm that you reference, you designate a function that specifies whether that alarm needs to be in ALARM state, OK state, or INSUFFICIENT_DATA state. You can use operators (AND, OR and NOT) to combine multiple functions in a single expression. You can use parenthesis to logically group the functions in your expression.
You can use either alarm names or ARNs to reference the other alarms that are to be evaluated.
Functions can include the following:
ALARM("alarm-name or alarm-ARN")
is TRUE if the named alarm is in ALARM state.OK("alarm-name or alarm-ARN")
is TRUE if the named alarm is in OK state.INSUFFICIENT_DATA("alarm-name or alarm-ARN")
is TRUE if the named alarm is in INSUFFICIENT_DATA state.TRUE
always evaluates to TRUE.FALSE
always evaluates to FALSE.
TRUE and FALSE are useful for testing a complex
AlarmRule
structure, and for testing your alarm actions.Alarm names specified in
AlarmRule
can be surrounded with double-quotes (“), but do not have to be.The following are some examples of
AlarmRule
:ALARM(CPUUtilizationTooHigh) AND ALARM(DiskReadOpsTooHigh)
specifies that the composite alarm goes into ALARM state only if both CPUUtilizationTooHigh and DiskReadOpsTooHigh alarms are in ALARM state.ALARM(CPUUtilizationTooHigh) AND NOT ALARM(DeploymentInProgress)
specifies that the alarm goes to ALARM state if CPUUtilizationTooHigh is in ALARM state and DeploymentInProgress is not in ALARM state. This example reduces alarm noise during a known deployment window.(ALARM(CPUUtilizationTooHigh) OR ALARM(DiskReadOpsTooHigh)) AND OK(NetworkOutTooHigh)
goes into ALARM state if CPUUtilizationTooHigh OR DiskReadOpsTooHigh is in ALARM state, and if NetworkOutTooHigh is in OK state. This provides another example of using a composite alarm to prevent noise. This rule ensures that you are not notified with an alarm action on high CPU or disk usage if a known network problem is also occurring.
The
AlarmRule
can specify as many as 100 “children” alarms. TheAlarmRule
expression can have as many as 500 elements. Elements are child alarms, TRUE or FALSE statements, and parentheses.InsufficientDataActions (list) –
The actions to execute when this alarm transitions to the
INSUFFICIENT_DATA
state from any other state. Each action is specified as an Amazon Resource Name (ARN).Valid Values: ]
Amazon SNS actions:
arn:aws:sns:region:account-id:sns-topic-name
Lambda actions:
Invoke the latest version of a Lambda function:
arn:aws:lambda:region:account-id:function:function-name
Invoke a specific version of a Lambda function:
arn:aws:lambda:region:account-id:function:function-name:version-number
Invoke a function by using an alias Lambda function:
arn:aws:lambda:region:account-id:function:function-name:alias-name
(string) –
OKActions (list) –
The actions to execute when this alarm transitions to an
OK
state from any other state. Each action is specified as an Amazon Resource Name (ARN).Valid Values: ]
Amazon SNS actions:
arn:aws:sns:region:account-id:sns-topic-name
Lambda actions:
Invoke the latest version of a Lambda function:
arn:aws:lambda:region:account-id:function:function-name
Invoke a specific version of a Lambda function:
arn:aws:lambda:region:account-id:function:function-name:version-number
Invoke a function by using an alias Lambda function:
arn:aws:lambda:region:account-id:function:function-name:alias-name
(string) –
Tags (list) –
A list of key-value pairs to associate with the alarm. You can associate as many as 50 tags with an alarm. To be able to associate tags with the alarm when you create the alarm, you must have the
cloudwatch:TagResource
permission.Tags can help you organize and categorize your resources. You can also use them to scope user permissions by granting a user permission to access or change only resources with certain tag values.
If you are using this operation to update an existing alarm, any tags you specify in this parameter are ignored. To change the tags of an existing alarm, use TagResource or UntagResource.
(dict) –
A key-value pair associated with a CloudWatch resource.
Key (string) – [REQUIRED]
A string that you can use to assign a value. The combination of tag keys and values can help you organize and categorize your resources.
Value (string) – [REQUIRED]
The value for the specified tag key.
ActionsSuppressor (string) – Actions will be suppressed if the suppressor alarm is in the
ALARM
state.ActionsSuppressor
can be an AlarmName or an Amazon Resource Name (ARN) from an existing alarm.ActionsSuppressorWaitPeriod (integer) –
The maximum time in seconds that the composite alarm waits for the suppressor alarm to go into the
ALARM
state. After this time, the composite alarm performs its actions.Warning
WaitPeriod
is required only whenActionsSuppressor
is specified.ActionsSuppressorExtensionPeriod (integer) –
The maximum time in seconds that the composite alarm waits after suppressor alarm goes out of the
ALARM
state. After this time, the composite alarm performs its actions.Warning
ExtensionPeriod
is required only whenActionsSuppressor
is specified.
- Returns:
None
Exceptions